Sign In | Join Free | My qualitytoyschina.com
China ANGELS Dental Implant Solutions Center logo
ANGELS Dental Implant Solutions Center
ANGELS Dental Implant Solutions Center -- We want you smile easily
Verified Supplier

6 Years

Home > Dental Implants Abutment >

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

ANGELS Dental Implant Solutions Center
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Brand Name : ANGELS

Model Number : Nobel Biocare Active®

Certification : TUV CE, ISO13485, ISO9001

Place of Origin : China

MOQ : 10Pcs

Price : USD8~12/pc, included screw

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 500,000pcs/month

Delivery Time : 3~5 days

Packaging Details : 1pcs/bag

Material : Ti 6AI-4V ELI (Grade 5)

Warranty : 12 months

After-sale Service : Online Technical Support

Size : RP Ø 6

Properties : Implant Materials & Artificial Organs

Product Tolerance : +-0.01mm

Length : 9mm/13mm

REF No. : 36544 / 36545

Contact Now

Nobel Active Impression Coping Closed Tray Conical

Connection RP Ø 6 x 9mm/13mm (36544/36545)

Material:

Ti 6AI-4V ELI (Supply from Germany)

Reference Number:

36544

36545

Feature:
- Titanium interface abutment
- Precision machined up to ± 5µm
- Combination of high fatigue strength
- Superior level of biocompatibility
- Exterior retentions for more cementation bonding

Approved by CE, ISO 9001, ISO 13485

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Length 9 / 13 mm
Implant Platform Regular Platform (RP)
Diameter 6 mm
Material Titanium Alloy
Indication Single-unit
Connection Type Internal Conical Connection
Open or Closed Tray Closed Tray
Works with NobelActive, NobelActive TiUltra, NobelParallel CC, NobelParallel CC TiUltra, NobelReplace CC, NobelReplace CC PMC
Purpose

CAD/CAM prosthetic, Pre-fab prosthetic

NobelActive™

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Fig. 3

Direct impression copings designed for the open tray impression technique are produced in two emergence profiles for NP platform implants (Fig.3, top row) and three emergence profiles for RP implants (Fig.3, bottom row). NP impression copings are produced in one height of 14mm while RP impression copings are available in two heights, 14m and a low profile version of 10mm. Emergence profiles for NP impression copings are machined in 3.6 and 5.0mm. RP impression copings are offered in three emergence profiles of 3.6, 5.0 and 6.0mm Only NP (3.5mm) platform impression copings are color coded for identification (fuchsia). A Unigrip™ driver may be used to service the fixation screw for impression copings.

NobelReplace™, Replace™ Select, NobelSpeedy™ Replace

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Fig. 12

All of the implants in this product group are machined with a internal indexing feature in four implant/abutment platform diameters of 3.5, 4.3, 5.0 and 6.0mm. The indexing feature (Fig.12) consists of a tri-lobe design of platform diameter specific dimensions, making prosthetic components incompatible from platform diameter to platform diameter. Each platform diameter is color coded for easy platform diameter identification. 3.5mm platform implants are color coded fuchsia and identified as narrow platform (NP). 4.3mm platform implants are color coded yellow and identified as regular platform (RP). 5.0mm platform implants are color coded blue and identified as wide platform (WP). 6.0mm platform implants are color coded green and without any further identification designation.

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Fig. 13

NobelReplace™ implants are offered in two body geometries, parallel (Fig.13, left) and tapered (Fig.13, right). Both geometries surface treated area extends uniformly from the edge of the implant/abutment platform to the apical and a diminishing thread depth towards the apical of the implant. A small secondary groove is fashioned underneath the main V shaped threads to enhance initial stability. The tapered version is machined without cutting flutes (Fig.16) at the apical portion while the parallel version is produced with cutting flutes (Fig.14) . All four platform diameter tapered implants are available in four advertised lengths of 8,

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Fig. 14

10, 13 and 16mm. Although each tapered implant is actually 0.6mm longer than advertised. 3.5mm platform parallel wall geometry implants are produced in four (10, 11.5, 13, 15mm) lengths while all other platform diameter implants are offered in one additional length of 18mm. Although each parallel implant is actually 0.6mm longer than advertised. There are no parallel wall 6.0mm platform diameter implants available.

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Fig. 15

Replace™ Select implants are offered in two body geometries, parallel (Fig.15, left) and tapered (Fig.15, right). Both geometries have a machined collar of 1.5mm and are surface treated below the collar, extending to the apical. A V shaped thread pattern is common to both body geometries with a diminishing thread depth toward the apical of the implant. The tapered version is machined without cutting flutes (Fig.16) at the apical portion while the parallel version is produced with cutting flutes (Fig.14). All four platform diameter tapered implants are available in four advertised lengths of 8, 10, 13 and 16mm. Although

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm

Fig. 16

each tapered implant is actually 0.6mm longer than advertised. 3.5mm platform parallel wall geometry implants are produced in four (10, 11.5, 13, 15mm) lengths while 4.3 and 5.0mm platform diameter implants are offered in one additional length of 18mm. Although each parallel implant is actually 0.75mm shorter than advertised. There are no parallel wall 6.0mm platform diameter implants available.


Product Tags:

Nobel Active Impression Coping Closed Tray

      

13mm Length Impression Coping Closed Tray

      
Quality Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm wholesale

Nobel Active Impression Coping Closed Tray Conical Connection RP Ø 6 x 9mm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ANGELS Dental Implant Solutions Center
*Subject:
*Message:
Characters Remaining: (0/3000)